18 December 2014 EMEA/CHMP/BMWP/42832/2005 Rev1 Committee for Medicinal Products for Human Use (CHMP) PPT/PDF

Recommended

Description

18 December 2014
EMEA/CHMP/BMWP/42832/2005 Rev1
Committee for Medicinal Products for Human Use (CHMP)

Guideline on similar biological medicinal products
containing biotechnology-derived proteins as active
substance: non-clinical and clinical issues

Draft agreed by Biosimilar Medicinal Products Working Party (BMWP) April 2013

Adopted by CHMP for release for consultation 30 May 2013

Start of public consultation 03 June 2013

End of consultation (deadline for comments) 30 November 2013

Agreed by Biosimilar Medicinal Products Working Party (BMWP) October 2014

Adopted by CHMP 18 December 2014

Date for coming into effect 01 July 2015

This guideline replaces ‘Guideline on similar biological medicinal products containing biotechnology-
derived proteins as active substance: Non-clinical and clinical issues’
(EMEA/CHMP/BMWP/42832/2005).

Keywords similar biological medicinal product, recombinant proteins, non-clinical
studies, clinical studies, safety, pharmacovigilance, immunogenicity

 

30 Churchill Place ● Canary Wharf ● London E14 5EU ● United Kingdom
Telephone +44 (0)20 3660 6000 Facsimile +44 (0)20 3660 5555
Send a question via our website www.ema.europa.eu/contact An agency of the European Union

© European Medicines Agency, 2015. Reproduction is authorised provided the source is acknowledged.

 

Guideline on similar biological medicinal products
containing biotechnology-derived proteins as active
substance: non-clinical and clinical issues
Table of contents
Executive summary …………………………………………………………………………. 3
1. Introduction ……………………………………………………………………………….. 3
2. Scope…………………………………………………………………………………………. 4
3. Legal basis and relevant guidelines ………………………………………………… 4
4. Non-clinical studies ……………………………………………………………………… 5
4.1. Step 1: In vitro studies …………………………………………………………………………….. 5
4.2. Step 2: Determination of the need for in vivo studies ………………………………………… 6
4.3. Step 3: In vivo studies ……………………………………………………………………………… 6
5. Clinical studies ……………………………………………………………………………. 7
5.1. Pharmacokinetic studies ……………………………………………………………………………. 8
5.2. Pharmacodynamic studies …………………………………………………………………………. 9
5.3. Efficacy trials …………………………………………………………………………………………. 9
5.3.1. Study designs ……………………………………………………………………………………. 10
5.3.2. Efficacy endpoints ……………………………………………………………………………….. 10
5.4. Clinical safety ………………………………………………………………………………………. 11
6. Extrapolation of efficacy and safety from one therapeutic indication to
another ………………………………………………………………………………………… 12
7. Pharmacovigilance …………………………………………………………………….. 12

 

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 2/13

 

Executive summary
The Guideline on similar biological medicinal products containing biotechnology-derived proteins as
active substance: non-clinical and clinical issues (EMEA/CHMP/BMWP/42832/05 Rev.1) lays down the
non-clinical and clinical requirements for a similar biological medicinal product (“biosimilar”).

The non-clinical section addresses the pharmaco-toxicological assessment. The clinical section
addresses the requirements for pharmacokinetic, pharmacodynamic, and efficacy studies. The section
on clinical safety and pharmacovigilance addresses clinical safety studies, including immunogenicity, as
well as the risk management plan.

The current revision covers the following topics: a stepwise approach for the design of non-clinical
studies; the use of pharmacodynamic markers; study design, choice of appropriate patient population
and choice of surrogate and clinical endpoints in efficacy trials; clinical safety (including design of
immunogenicity studies), risk management plan, and pharmacovigilance, and extrapolation of safety
and efficacy. The guideline recommends a stepwise conduct of non-clinical and clinical studies.

1. Introduction
A biosimilar is a biological medicinal product that contains a version of the active substance of an
already authorised original biological medicinal product (reference medicinal product) in the European
Economic Area (EEA). Similarity to the reference medicinal product in terms of quality characteristics,
biological activity, safety and efficacy based on a comprehensive comparability exercise needs to be
established.

The Marketing Authorisation (MA) application dossier of a biosimilar medicinal product shall provide a
full quality dossier together with data demonstrating comparability with the reference medicinal
product by using appropriate physico-chemical and in vitro biological tests, non-clinical studies and
clinical studies.

The quality issues relevant for demonstration of biosimilar comparability are addressed in the Guideline
on similar biological medicinal products containing biotechnology-derived proteins as active
substances: quality issues (EMA/CHMP/BWP/247713/2012).

The principles for the non-clinical and clinical parts of the biosimilar comparability exercise are laid
down in this guideline. Product class specific guidelines will supplement this guideline where a need is
identified.

The nature and complexity of the reference product have an impact on the extent of the (non)clinical
studies to confirm biosimilarity. The differences observed in the physico-chemical and biological
analyses will guide the planning of the (non-)clinical studies. Other factors that need to be taken into
consideration are the mode of action of the active substance (e.g. receptor(s) involved) in all the
authorised indications of the reference product and pathogenic mechanisms involved in the disorders
included in the therapeutic indications (e.g. mechanisms shared by various therapeutic indications) as
well as the immunogenicity of the reference medicinal product.

The applicant should review data from the reference product on the predictive value of in vitro
assays/animal models as well as correlations between dose/exposure and pharmacodynamics. In
addition, the applicant should look at the correlation between pharmacodynamics and clinical response.
The availability of suitable biomarkers may abbreviate the (non-)clinical development. The safety
profile of the reference product will mainly determine the focus of the clinical safety studies both pre-
and post-authorisation.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 3/13

 

If the biosimilar comparability exercise indicates that there are relevant differences between the
biosimilar and the reference medicinal product, making it unlikely that biosimilarity will eventually be
established, a stand-alone development to support a full Marketing Authorisation Application, should be
considered instead (see “Guideline on similar biological products” (CHMP/437/04 Rev. 1)).

2. Scope
This guideline addresses the general principles for the non-clinical and clinical development and
assessment of the marketing authorisation applications of biosimilars containing biotechnology-derived
proteins as active substance(s). Nevertheless, the principles explained in this document could apply to
other biological products, on a case by case basis. This guideline does not address the comparability
exercise for changes introduced in the manufacturing process of a given product (i.e. changes during
development and post-authorisation).

3. Legal basis and relevant guidelines
• Directive 2001/83/EC, as amended in particular Directive 2001/83/EC Art 10(4) and Part II of

the Annex I of Directive 2001/83/EC, as amended.

• Directive 2010/63/EU on the protection of animals used for scientific purposes.

For the relevant CHMP/ICH guidelines, please see the website of the European medicines Agency
(http://www.ema.europa.eu): Human medicines > Scientific guidelines > Multidisciplinary >
Biosimilar. In particular, the following guidelines should be read in conjunction:

• Guideline on similar biological products (CHMP/437/04 Rev. 1), the so-called ‘overarching
guideline’

• Guideline on similar biological medicinal products containing biotechnology-derived proteins as
active substance – quality issues (EMA/CHMP/BWP/247713/2012)

• Q5E Comparability of biotechnological/biological products (CPMP/ICH/5721/03)

• ICH topic E9 statistical principles for clinical trials – Note for guidance on statistical principles for
clinical trials (CPMP/ICH/363/96)

• Guideline on the choice of the non-inferiority margin (CPMP/EWP/2158/99)

• ICH topic E10 – Note for guidance on choice of control group in clinical trials (CPMP/ICH/364/96)

• Guideline on Immunogenicity assessment of biotechnology-derived therapeutic proteins
(EMEA/CHMP/BMWP/14327/2006)

• Guideline on Immunogenicity assessment of monoclonal antibodies intended for in vivo clinical
use (EMA/CHMP/BMWP/86289/2010)

• Guideline on the clinical investigation of the pharmacokinetics of therapeutic proteins
(CHMP/EWP/89249/2004)

• Guideline on the investigation of bioequivalence (CPMP/EWP/QWP/1401/98 Rev. 1/ Corr)

• Guideline on bioanalytical method validation (EMEA/CHMP/EWP/192217/2009)

• Product class-specific guidelines on various biosimilar products

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 4/13

 

• Guidelines on good pharmacovigilance practices (please see the website of the European
medicines Agency (http://www.ema.europa.eu) – Human regulatory – Pharmacovigilance –
Good Pharmacovigilance Practices)

4. Non-clinical studies
To support biosimilarity, relevant non-clinical studies should be performed before initiating clinical
trials. A stepwise approach is recommended for evaluation of the similarity of the biosimilar and the
reference product. Analytical studies (see Guideline on similar biological medicinal products containing
biotechnology-derived proteins as active substance – quality issues) and in vitro pharmaco-
toxicological studies should be conducted first and a decision then made as to the extent of what, if
any, in vivo work in animal studies will be required.

It is important to note that, to design an appropriate non-clinical study programme, a clear
understanding of the reference product characteristics is required. Results from the physico-chemical
and biological characterisation studies (i.e. comparability of the biosimilar to the reference product)
should be reviewed from the point-of-view of potential impact on efficacy and safety.

The following approach may be considered and should be tailored to the product concerned on a case-
by-case basis. The approach taken will need to be fully justified in the non-clinical overview.

4.1. Step 1: In vitro studies

In order to assess any potential difference in biological activity between the biosimilar and the
reference medicinal product, data from a number of comparative in vitro studies, some of which may
already be available from quality-related assays, should normally be provided.

These studies should include relevant assays on:

– Binding to target(s) (e.g. receptors, antigens, enzymes) known to be involved in the pharmaco-
toxicological effects and/or pharmacokinetics of the reference product.

– Signal transduction and functional activity/viability of cells known to be of relevance for the
pharmaco-toxicological effects of the reference product.

The studies should be comparative in nature and should not just assess the response per se. To obtain
unambiguous results, the methods used should be scientifically valid and suitable for their purpose.

The studies should be sensitive, specific and sufficiently discriminatory to provide evidence that
observed differences in quality attributes are clinically not relevant. The studies should compare the
concentration–activity/binding relationship of the biosimilar and the reference medicinal product at the
pharmacological target(s), covering a concentration range where potential differences are most
sensitively detected.

They should be performed with an appropriate number of batches of the reference product and of the
biosimilar representative of the material intended for clinical use. Assay and batch-to-batch variability
will affect the number needed. The number tested should be sufficient to draw meaningful conclusions
on the variability of a given parameter for both the biosimilar and the reference product and on the
similarity of both products.

Together, these assays should cover the whole spectrum of pharmacological/toxicological aspects
known to be of clinical relevance for the reference product and for the product class.

The applicant should discuss to what degree the in vitro assays used are representative/predictive for
the clinical situation according to current scientific knowledge.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 5/13

 

Since in vitro assays may often be more specific and sensitive to detect differences between the
biosimilar and the reference product than studies in animals, these assays can be considered as
paramount for the non-clinical biosimilar comparability exercise.

4.2. Step 2: Determination of the need for in vivo studies

It is acknowledged that biotechnology-derived proteins may mediate in vivo effects that cannot be fully
elucidated by in vitro studies. Therefore, non-clinical evaluation in in vivo studies may be necessary to
provide complementary information, provided that a relevant in vivo model with regard to species or
design is available.

Factors to be considered when the need for in vivo non-clinical studies is evaluated, include, but are
not restricted to:

• Presence of potentially relevant quality attributes that have not been detected in the reference
product (e.g. new post-translational modification structures).

• Presence of potentially relevant quantitative differences in quality attributes between the
biosimilar and the reference product.

• Relevant differences in formulation, e.g. use of excipients not widely used for biotechnology-
derived proteins.

Although each of the factors mentioned above do not necessarily warrant in vivo testing, these issues
should be considered together to assess the level of concern and whether there is a need for in vivo
testing.

If the biosimilar comparability exercise for the physicochemical and biological characteristics and the
non-clinical in vitro studies (see step 1) are considered satisfactory and no issues are identified in
step 2 which would block direct entrance into humans, an in vivo animal study is usually not
considered necessary.

If product-inherent factors that impact PK and/or biodistribution, like extensive glycosylation, cannot
sufficiently be characterised on a quality and in vitro level, in vivo studies may be necessary. The
Applicant should then carefully consider if these should be performed in animals or as part of the
clinical testing, e.g. in healthy volunteers.

If there is a need for additional in vivo information, the availability of a relevant animal species or
other relevant models (e.g. transgenic animals, transplant models) should be considered.

If a relevant in vivo animal model is not available, the applicant may choose to proceed to human
studies taking into account principles to mitigate any potential risk.

4.3. Step 3: In vivo studies

If an in vivo evaluation is deemed necessary, the focus of the study/studies (PK and/or PD and/or
safety) depends on the need for additional information. Animal studies should be designed to maximise
the information obtained. The principles of the 3Rs (replacement, refinement, reduction) according to
Article 4 of Directive 2010/63/EU should be considered when designing any in vivo study. Depending
on the endpoints used, it may not be necessary to sacrifice the animals at the end of the study. The
duration of the study (including observation period) should be justified, taking into consideration the
PK behaviour of the reference medicinal product and its clinical use.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 6/13

 

When the model allows and if not otherwise justified, the PK and PD of the biosimilar and the reference
medicinal product should be quantitatively compared, including, if feasible, a dose concentration-
response assessment including the intended exposure in humans.

For safety studies a flexible approach should be considered, in particular if non-human primates are
the only relevant species. The conduct of standard repeated dose toxicity studies in non-human
primates is usually not recommended. If appropriately justified, a repeated dose toxicity study with
refined design (e.g. using just one dose level of biosimilar and reference product and/or just one
gender and/or no recovery animals) or an in-life evaluation of safety parameters (such as clinical
signs, body weight and vital functions) may be considered. For repeated dose toxicity studies where
only one dose is evaluated, this would usually be selected at the high end of the dosing range and
should be justified on the basis of expected toxicity of the reference medicinal product.

The conduct of toxicity studies in non-relevant species (i.e. to assess unspecific toxicity only, based on
impurities) is not recommended. Due to the different production processes used by the biosimilar and
reference product manufacturers, qualitative differences of process related impurities can occur (e.g.
host cell proteins). The level of such impurities should be kept to a minimum, which is the best
strategy to minimise any associated risk.

Qualitative or quantitative difference(s) of product-related variants (e.g. glycosylation patterns, charge
variants) may affect biological functions of the biotechnology-derived protein and are expected to be
evaluated by appropriate in vitro assays. These differences and impurities may have an effect on
immunogenic potential and the potential to cause hypersensitivity. It is acknowledged that these
effects are difficult to predict from animal studies and should be further assessed in clinical studies.

Although immunogenicity assessment in animals is generally not predictive for immunogenicity in
humans, it may be needed for interpretation of in vivo studies in animals. Therefore, blood samples
should be taken and stored for future evaluations of pharmacokinetic/toxicokinetic data if then needed.

Studies regarding safety pharmacology, reproduction toxicology, and carcinogenicity are not required
for non-clinical testing of biosimilars.

Studies on local tolerance are usually not required. However, if excipients are introduced for which
there is no or little experience with the intended clinical route of administration, local tolerance may
need to be evaluated. If other in vivo studies are performed, evaluation of local tolerance may be part
of the design of that study instead of the performance of separate local tolerance studies.

5. Clinical studies
It is acknowledged that the manufacturing process of the biosimilar product will be optimised during
development. However, it is recommended to generate the clinical data required for the biosimilar
comparability exercise with the biosimilar product derived from the commercial manufacturing process
and therefore representing the quality profile of the batches to become commercialised. Any deviation
from this recommendation should be justified and supported by adequate additional bridging data (as
described in guideline ICH Q5E).

The clinical biosimilar comparability exercise is normally a stepwise procedure that should begin with
pharmacokinetic (PK) and, if feasible, pharmacodynamic (PD) studies followed by clinical efficacy and
safety trial(s) or, in certain cases, confirmatory PK / PD studies for demonstrating clinical biosimilar
comparability.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 7/13

 

5.1. Pharmacokinetic studies

Comparative pharmacokinetic (PK) studies designed to demonstrate similar PK profile of the biosimilar
and the reference medicinal product with regard to key PK parameters are an essential part of the
biosimilar development programme.

The design of a PK study depends on various factors, including clinical context, safety, PK
characteristics of the reference product (target-mediated disposition, linear or non-linear PK, time-
dependency, half-life, etc.) as outlined in the Guideline on the clinical investigation of the
pharmacokinetics of therapeutic proteins (CHMP/EWP/89249/2004) and, as applicable, the Guideline
on the investigation of bioequivalence (CPMP/EWP/QWP/1401/98 Rev. 1/ Corr). Furthermore,
bioanalytical assays should be appropriate for their intended use and adequately validated as outlined
in the Guideline on bioanalytical method validation (EMEA/CHMP/EWP/192217/2009).

The biosimilar comparability limits for the main PK parameters should be defined and justified prior to
conducting the study. The criteria used in standard clinical bioequivalence studies, initially developed
for chemically derived, orally administered products, may be a reasonable basis for planning
comparative pharmacokinetic trials for biologicals in the absence of specific criteria. However, the
interpretation of bioequivalence studies for biologicals is less straightforward than for small molecules.
In the latter case the molecules are considered identical, whilst for biologicals, PK is used to detect
possible differences in the interaction with the body between the originator and the biosimilar. This
means that observing 90% CIs of ratios of biosimilar to reference product within a pre-specified,
justified acceptance range may not, by itself, be sufficient. The location and the width of the
confidence interval should also be taken into account in the interpretation of similarity. For example,
statistically significant differences in 90% CIs within the justified acceptance range regarding relevant
PK parameters would need to be explained and justified as not to preclude biosimilarity. On the other
hand, if the 90% CI crosses the prespecified boundaries the applicant would need to explain such
difference and explore root causes. Correction for protein content may be acceptable on a case-by-
case basis if pre-specified and adequately justified, with the results from the assay of the test and
reference products being included in the protocol.

Although the comparison of target-mediated clearance is of major importance in the biosimilarity
exercise, it may not be feasible in patients due to major variability in target expression, including
variability over time. However, since in vitro studies are expected to show comparable interaction
between the biosimilar and its target(s) (including FcRn for a mab), the absence of a pivotal PK study
in the target population is acceptable, if additional PK data are collected during the efficacy, safety
and/or PD studies as this allows further investigation of the clinical impact of variable pharmacokinetics
and possible changes in the PK over time. This can be achieved by determining the PK profile in a
subset of patients or by population pharmacokinetics.

A single dose cross-over study with full characterisation of the PK profile, including the late elimination
phase, is preferable. A parallel group design may be necessary with substances with a long half-life
and/or a high risk of immunogenicity. The doses in the single dose PK biosimilar comparability study in
healthy volunteers may be lower than the recommended therapeutic doses. PK studies are not always
feasible in healthy volunteers. In this case, the PK needs to be studied in patients as part of a multiple
dose study, if a single dose study is not feasible. A sensitive model/population, i.e. that has fewer
factors that cause major inter-individual or time-dependent variation, should be explored.

If the reference product can be administered both intravenously and subcutaneously, the evaluation of
subcutaneous administration will usually be sufficient as it covers both absorption and elimination.
Thus, it is possible to waive the evaluation of intravenous administration if biosimilar comparability in
both absorption and elimination has been demonstrated for the subcutaneous route. Omission of the

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 8/13

 

PK study of intravenous administration needs to be justified, e.g., in cases when the molecule has an
absorption constant which is much slower than the elimination constant (flip flop kinetics).

In a single dose PK study, the primary parameters are the AUC(0-inf) for intravenous administration and

AUC(0-inf) and usually Cmax for subcutaneous administration. Secondary parameters such as tmax, volume
of distribution, and half-life, should also be estimated. In a multiple dose study, the primary
parameters should be the truncated AUC after the first administration until the second administration
(AUC0-t) and AUC over a dosage interval at steady state (AUC). Secondary parameters are Cmax and
Ctrough at steady state.

In any PK study, anti-drug antibodies should be measured in parallel to PK assessment using
appropriate sampling time points.

5.2. Pharmacodynamic studies

It is recommended that pharmacodynamic (PD) markers are added to the pharmacokinetic studies
whenever feasible. The PD markers should be selected on the basis of their relevance to the clinical
outcome.

In certain cases, comparative PK/PD studies may be sufficient to demonstrate clinical comparability of
the biosimilar and the reference medicinal product, provided that the following conditions are met:

• The selected PD marker/biomarker is an accepted surrogate marker and can be related to
patient outcome to the extent that demonstration of similar effect on the PD marker will ensure
a similar effect on the clinical outcome. Relevant examples include absolute neutrophil count to
assess the effect of granulocyte-colony stimulating factor (G-CSF), early viral load reduction in
chronic hepatitis C to assess the effect of alpha interferons, and euglycaemic clamp test to
compare two insulins. Magnetic resonance imaging of disease lesions can be used to compare
two β-interferons in multiple sclerosis.

• There may be PD-markers that are not established surrogates for efficacy but are relevant for
the pharmacological action of the active substance and a clear dose-response or a concentration-
response relationship has been demonstrated. In this case, a single or multiple dose-exposure-
response study at two or more dose levels may be sufficient to waive a clinical efficacy study.
This design would ensure that the biosimilar and the reference can be compared within the steep
part of the dose response curve (assay sensitivity, see ICH topic E10).

• In exceptional cases, the confirmatory clinical trial may be waived if physicochemical, structural
and in vitro biological analyses and human PK studies together with a combination of PD markers
that reflect the pharmacological action and concentration of the active substance, can provide
robust evidence for biosimilar comparability.

When evidence to establish clinical biosimilar comparability will be derived from PK studies supported
by studies with non-surrogate PD/biomarkers, it is recommended to discuss such (“fingerprinting”)
approach with regulatory authorities. The plan should include a proposal of the size of the equivalence
margin(s) with its clinical justification as well as of the measures for demonstration of a comparable
safety profile.

5.3. Efficacy trials

In the absence of surrogate markers for efficacy, it is usually necessary to demonstrate comparable
clinical efficacy of the biosimilar and the reference medicinal product in adequately powered,
randomised, parallel group comparative clinical trial(s), preferably double-blind, by using efficacy

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 9/13

 

endpoints. The study population should generally be representative of approved therapeutic
indication(s) of the reference product and be sensitive for detecting potential differences between the
biosimilar and the reference. Occasionally, changes in clinical practice may require a deviation from the
approved therapeutic indication, e.g. in terms of concomitant medication used in a combination
treatment, line of therapy, or severity of the disease. Deviations need to be justified and discussed
with regulatory authorities.

5.3.1. Study designs

In general, an equivalence design should be used. The use of a non-inferiority design may be
acceptable if justified on the basis of a strong scientific rationale and taking into consideration the
characteristics of the reference product, e.g. safety profile/tolerability, dose range, dose-response
relationship. A non-inferiority trial may only be accepted where the possibility of significant and
clinically relevant increase in efficacy can be excluded on scientific and mechanistic grounds. However,
as in equivalence trials, assay sensitivity has to be considered.

It is recommended to discuss the use of a non-inferiority design with regulatory authorities.

5.3.2. Efficacy endpoints

Efficacy trials of biosimilar medicinal products do not aim at demonstrating efficacy per se, since this
has already been established with the reference product. The purpose of the efficacy trials is to confirm
comparable clinical performance of the biosimilar and the reference product.

CHMP has issued disease-specific guidelines for development of innovative medicinal products. In the
development of a biosimilar medicinal product, the choice of clinical endpoints and time points of
analysis of endpoints may deviate from the guidance for new active substances. Therefore, CHMP has
issued product-class-specific guidelines to guide the development of biosimilar medicinal products in
certain areas. In the absence of such a guideline, comparability should be demonstrated in
appropriately sensitive clinical models and study conditions. The applicant should justify that the
chosen model is relevant and sensitive to detect potential differences with regard to efficacy and
safety. Nevertheless, deviations from endpoints recommended in disease-specific guidelines need to be
scientifically justified. Differences detected between the efficacy of the biosimilar and reference
products should always be discussed as to whether they are clinically relevant. Generally, the aim of
clinical data is to address slight differences observed at previous steps and to confirm comparable
clinical performance of the biosimilar and the reference product. Clinical data cannot be used to justify
substantial differences in quality attributes.

The correlation between the “hard” clinical endpoints recommended by the guidelines for new active
substances and other clinical/pharmacodynamic endpoints that are more sensitive to detect clinically
meaningful differences may have been demonstrated in previous clinical trials with the reference
product. In this case, it is not necessary to use the same primary efficacy endpoints as those that were
used in the marketing authorisation application of the reference product. However, it is advisable to
include some common endpoints (e.g. as secondary endpoints) to facilitate comparisons to the clinical
trials conducted with the reference product.

Comparability margins should be pre-specified and justified on both statistical and clinical grounds by
using the data of the reference product (see ICH topic E9 Statistical principles for clinical trials and
CHMP guideline CPMP/EWP/2158/99 on the choice of the non-inferiority margin). As for all comparative
clinical trial designs, assay sensitivity (see ICH topic E10) has to be considered.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 10/13

 

5.4. Clinical safety

Clinical safety is important throughout the clinical development programme and is captured during
initial PK and/or PD evaluations and also as part of the pivotal clinical efficacy study. Comparative
safety data should normally be collected pre-authorisation, their amount depending on the type and
severity of safety issues known for the reference product. The duration of safety follow-up pre-
authorisation should be justified. Care should be given to compare the type, severity and frequency of
the adverse reactions between the biosimilar and the reference product, particularly those described in
the SmPC of the reference product. The applicant should provide in the application dossier an
evaluation of the specific risks anticipated for the biosimilar. This includes in particular a description of
possible safety concerns that may result from a manufacturing process different from that of the
reference product, especially those related to infusion-related reactions and immunogenicity.

The principles for the assessment of immunogenicity of therapeutic proteins and monoclonal antibodies
have been described in two CHMP guidelines (EMEA/CHMP/BMWP/14327/2006;
EMA/CHMP/BMWP/86289/2010). The potential for immunogenicity of a biosimilar should be
investigated in a comparative manner to the reference product and should follow the principles as laid
down in the aforementioned CHMP guidelines unless it can be justified that there is a need for
deviation from this approach. The type and amount of immunogenicity data will depend on the
experience gained with the reference product and the product class.

Immunogenicity testing of the biosimilar and the reference product should be conducted within the
biosimilar comparability exercise by using the same assay format and sampling schedule which must
meet all current standards. Analytical assays should be performed with both the reference and
biosimilar molecule in parallel (in a blinded fashion) to measure the immune response against the
product that was received by each patient. The analytical assays should preferably be capable of
detecting antibodies against both the biosimilar and the reference molecule but should at least be able
to detect all antibodies developed against the biosimilar molecule. Usually, the incidence and nature
(e.g. cross-reactivity, target epitopes and neutralising activity) of antibodies and antibody titres should
be measured and presented and should be assessed and interpreted in relation to their potential effect
on clinical efficacy and safety parameters.

Duration of the immunogenicity study should be justified on a case-by-case basis depending on the
duration of the treatment course, disappearance of the product from the circulation (to avoid antigen
interference in the assays) and the time for emergence of humoral immune response (at least four
weeks when an immunosuppressive agent is used). Duration of follow-up should be justified based on
the time course and characteristics of unwanted immune responses described for the reference
medicinal product, e.g. a low risk of clinically significant immunogenicity or no significant trend for
increased immunogenicity over time. In case of chronic administration, one-year follow up data will
normally be required pre-authorisation. Shorter follow-up data pre-authorisation (e.g. 6 months) might
be justified based on the immunogenicity profile of the reference product. If needed, immunogenicity
data for an additional period, up to one-year, could then be submitted post-authorisation. For specific
products, refer to product specific biosimilar guidance.

Increased immunogenicity as compared to the reference product may become an issue for the
benefit/risk analysis and would question biosimilarity. However, also a lower immunogenicity for the
biosimilar is a possible scenario, which would not preclude approval as a biosimilar. In case of reduced
development of neutralizing antibodies with the biosimilar, the efficacy analysis of the entire study
population could erroneously suggest that the biosimilar is more efficacious than the reference product.
It is therefore recommended to pre-specify an additional exploratory subgroup analysis of efficacy and
safety in those patients that did not mount an anti-drug antibody response during the clinical trial. This

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 11/13

 

subgroup analysis could be helpful to establish that the efficacy of the biosimilar and the reference
product are in principle similar if not impacted by an immune response.

6. Extrapolation of efficacy and safety from one therapeutic
indication to another
The reference medicinal product may have more than one therapeutic indication. When biosimilar
comparability has been demonstrated in one indication, extrapolation of clinical data to other
indications of the reference product could be acceptable, but needs to be scientifically justified. In case
it is unclear whether the safety and efficacy confirmed in one indication would be relevant for another
indication, additional data will be required. Extrapolation should be considered in the light of the
totality of data, i.e. quality, non-clinical and clinical data. It is expected that the safety and efficacy can
be extrapolated when biosimilar comparability has been demonstrated by thorough physico-chemical
and structural analyses as well as by in vitro functional tests complemented with clinical data (efficacy
and safety and/or PK/PD data) in one therapeutic indication. Additional data are required in certain
situations, such as

1. the active substance of the reference product interacts with several receptors that may have a
different impact in the tested and non-tested therapeutic indications

2. the active substance itself has more than one active site and the sites may have a different
impact in different therapeutic indications

3. the studied therapeutic indication is not relevant for the others in terms of efficacy or safety,
i.e. is not sensitive for differences in all relevant aspects of efficacy and safety.

Immunogenicity is related to multiple factors including the route of administration, dosing regimen,
patient-related factors and disease-related factors (e.g. co-medication, type of disease, immune
status). Thus, immunogenicity could differ among indications. Extrapolation of immunogenicity from
the studied indication/route of administration to other uses of the reference product should be justified.

7. Pharmacovigilance
Data from pre-authorisation clinical studies are usually insufficient to identify rare adverse effects.
Therefore, clinical safety of biosimilars must be monitored closely on an ongoing basis during the post-
approval phase including continued benefit-risk assessment.

Within the authorisation procedure the applicant should present a description of the pharmacovigilance
system and a risk management plan in accordance with current EU legislation and pharmacovigilance
guidelines. The risk management plan should take into account identified and potential risks associated
with the use of the reference product and should detail how these issues will be addressed in post-
marketing follow-up. Immunogenicity should specifically be addressed in this context. Any specific
safety monitoring imposed on the reference medicinal product or product class should be adequately
addressed in the pharmacovigilance plan of the biosimilar. Applicants are encouraged to participate in
already existing pharmacoepidemiological studies in place for the reference product. However, new
studies might have to be initiated. Risk minimisation activities in place for the reference medicinal
product should, in principle, also be included into the risk management programme of the biosimilar.
Any deviation from this (e.g. when the risk minimisation is linked to the device used with the reference
product) should be justified.

For suspected adverse reactions relating to biological medicinal products, the definite identification of
the concerned product with regard to its manufacturing is of particular importance. Therefore, all

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 12/13

 

appropriate measures should be taken to identify clearly any biological medicinal product which is the
subject of a suspected adverse reaction report, with due regard to its brand name and batch number.

Guideline on similar biological medicinal products containing biotechnology-derived
proteins as active substance: non-clinical and clinical issues
EMEA/CHMP/BMWP/42832/2005 Rev1 Page 13/13